DESIGNING AND MANUFACTURING TRITIUM MANAGEMENT TECHNOLOGY.

Tyne USA
Tyne USA
  • Home
  • Tritium Monitoring System
  • Tritium Collection System
  • Tritium Handling system
  • Tritium Storage System
  • SMR Tritium Management
  • Tritium Detection Systems
  • CGD Services
  • Reverse Engineering
  • Special Applications
  • Nuclear Power Components
  • About
  • Contact us
  • More
    • Home
    • Tritium Monitoring System
    • Tritium Collection System
    • Tritium Handling system
    • Tritium Storage System
    • SMR Tritium Management
    • Tritium Detection Systems
    • CGD Services
    • Reverse Engineering
    • Special Applications
    • Nuclear Power Components
    • About
    • Contact us
  • Home
  • Tritium Monitoring System
  • Tritium Collection System
  • Tritium Handling system
  • Tritium Storage System
  • SMR Tritium Management
  • Tritium Detection Systems
  • CGD Services
  • Reverse Engineering
  • Special Applications
  • Nuclear Power Components
  • About
  • Contact us

Wall Mount Room tritium in air monitor

Wall Mount Room Tritium In Air Monitor Model 7065

Tyne Engineering's Wall Mounted Room Tritium In Air Monitor: Model 7065 is intended for room monitoring for both tritium and gamma with the convenience of simple wall mounting for ease of removal for calibration or relocation.  The 7065 instrument is based on the same platform used in Tyne’s successful Portable Tritium-In-Air Monitor: Model 7043. 

features: WALL MOUNT ROOM TRITIUM IN AIR MONITOR

The wall mount version employs four ion chambers that are approximately 3 times larger than those used in their Model 7043 hand held instrument, hence increasing sensitivity by a factor of 3.   The wall mounted instrument also employs a larger and more powerful, low noise, and high reliability pump, which is easily accessible by removal of the front panel.  This room tritium monitor also allows for easy removal of the wireless transmitter for independent tune-up of this unit.


  • Simple to use, with only one operating switch with four settings: Off, Sample, Pump, Set Up.
  • Gamma Compensation with four large ion chambers arranged in a symmetrical configuration. Two chambers are used for measuring the air sample and the other two for compensation.
  • Better than 10% inaccuracy in 20 mR/hr field.
  • High Sensitivity. The current amplification circuit employs ultra-low leakage technology. Each chamber has an
    individual amplifier, improving the Signal-Noise Ratio of the analog circuit.
  • Radon compensation is provided by an analog filter circuit designed to separate the radon spike from the tritium signal. The unit’s software can distinguish the radon spike from the tritium signal occurring as a slow-change signal.
  • Ion-traps are built into each ion chamber.
  • Direct, wide range, gamma measurement is provided using an installed GM tube.
  • Decontamination is easily performed by purging the ion chambers while simultaneously heating them using a centrally installed cartridge heater.
  • Customer’s choice of hard-wired RS-232, Ethernet or an industry standard wireless connectivity.
  • Self monitoring with low air flow alarm.


Compensation for gamma background is crucial in tritium measurement because a gamma field of 1mR/Hr will generate 500 times the ionization generated by l uCi/m3 of tritium. Tyne designed the four ion chambers in a symmetrical arrangement with each chamber connected to an ultra sensitive electrometer amplifier and filter. All signals pass through an ADC converter and a micro-processor calculates and displays the measured tritium values. The micro-processor also monitors air flow rate using a solid-state flow meter and controls the chamber temperatures during the heated purge cycle.  A separate small ion chamber is used to cover higher tritium concentration ranges.


The front mounted LCD screen is a touch sensitive screen used to control device settings such as alarm levels. The instrument has both visual and audible alarm annunciation. The audible alarm can be canceled without canceling the visual annunciation. The touch screen panel is accessed by a two level password system. One password provides high level access allowing exclusive personnel to set up the device and the other provides restricted access enabling operators to only adjust certain features. The touch screen is augmented by use of a large digital read-out providing better, longer distance, visibility for operators.


The unit employs a front mounted high efficiency inlet air filter to ensure that the ion chambers do not become contaminated. If required, a sniffer probe adapter can be provided. The sniffer allows operators to locate suspected tritium leaks in the facility.  For example, sniffing around a seal or flange to identify leaks.


Instrument output includes external communication via RS232, Ethernet and industry standard wireless to enable downloading or recording of information on a computer. The thin-film transistor (TFT) color LCD display mounted on the surface plate clearly displays instrument readings in both digital and graphic format showing real time measurements and trends.


The large ion chambers, configured in a compact internal module, enable a sensitivity that precludes the need for Methane or P-10 counting gases and the use of less reliable flow proportional counting systems.  The ion chambers are robust and reliable, but if they become contaminated they can be purged by using an internally mounted heater while simultaneously pumping dry air through the chambers.


This wall mounted unit is powered by internal power supplies and only needs a standard 120 VAC three prong outlet to operate.


SPECIFICATIONS


Measuring chamber effective volume   1.5L,(2X0.75L)

Pump  Positive displacement gas pump: 12 VDC, flow rate up to 8 L/min, discharge pressure up to 30 psig, up to 90% relative vacuum

Tritium measuring range   0.2μCi/m3 (7,400Bq/ m3) to 1Ci/m3(3.7E10 Bq/m3)

Ion Chamber Configuration  Cruciform configuration: two for measuring and two for compensation

Radiation measured   Total tritium and total gamma

Sensitivity 0.2μCi/m3 (0.01 DAC)

Accuracy   0.4μCi/m3 from 0 μCi/m3 to 100μCi/ m3; ±10% from 100μCi/ m3 to 1Ci/ m3

Zero stability   ±0.4μCi/ m3

Gamma measurement   Gamma is measured simultaneously with tritium. Measuring range is from 0.1mR/ h to 10 R/hr

Radon compensation   Instrument provides radon compensation

Gamma background compensation   less than ±10% or 5μCi/m3 reading change whichever is greater response to 20mR/Hr

Ion trap   Built into each ion chamber
Flow rate  
Up to 8 L/min

Response time   2 to 5s with 0-15 m air hose, within 30s with hose from 100 to 150m at 90% of signal

Drift   ±3% per 24 hrs; ±10% per 30 days

Alarms   Local audio and visual alarms for tritium, gamma, air flow, detector failure and micro processor failure. Remote data and alarm display via RS-232 or analog output (0 to 3 VDC)

Alarm Response   < 30S with 2-150m hose

Ion Chamber purge and decontamination  Chambers can be heated using an internal  temperature controlled cartridge heater

Condensation Prevention   The heater cartridge temperature can be raised above ambient temperature to prevent condensation in instrument

Communication port   RS232 (short distance)

Data Communication   Ethernet connection provided Industrial wireless connectivity optional

per customer specification

Data Logging Frequency   The tritium and gamma readings can be  logged at a defined interval. Each data reading is date and time stamped

Displays   One 2.8” TFT LCD touch screen display showing the values of tritium and gamma radiation in both numerical and graphical format. One LED screen 6 x 3⁄4” digits showing tritium concentration

Power supply   120 VAC (±10%) Standard; 220VAC (±10%) upon request; Power consumption < 3A

Temperature   Operating Range 0 to 50°C degrees

Humidity Operating range   0-90%, Non-condensing

Size    Approx 13.25" High x 8.1” Deep x 18.25" Wide

Weight    Less than 30lbs with a steel case; Less than 22lbs with an aluminum case

Mounting    Unit is designed for wall mounting on a pre-installed wall plate. Unit hangs from two upper hooks and is retained by a single screw at the base for positive and secure installation

more about tritium monitoring

Tritium in Air Monitoring

Tritium in Process Tubing Monitoring

Tritium Surface Monitoring

Tritium in Air Monitoring: portable and room monitors, Tritium management system design for fusion

Tyne Engineering has designed and manufactured a wide range of tritium air monitors. Our products can be incorporated into customized tritium management system design requirements.  Applications include:

  • Medical
  • Academic & scientific
  • Industrial
  • Nuclear power plants


Find out more

Tritium Surface Monitoring

Tritium in Process Tubing Monitoring

Tritium Surface Monitoring

Tritium Surface Monitoring: surface area monitor design and manufacture, Tritium management systems.

 Tyne offers expedited delivery of two of their  popular surface activity monitors: 

  • Model 7001 works with flat or uneven surfaces by utilizing smear paper
  • Model 7019-SWTM-001 monitors soft waste such as paper, towels, clothing



Find out more

Tritium in Process Tubing Monitoring

Tritium in Process Tubing Monitoring

Tritium in Process Tubing Monitoring

Tritium in Process Tubing Monitoring, Tritium management system design for fusion energy , smr.

Tyne Engineering has developed instruments specifically for measuring tritium inside process lines. Applications include:

  • Tritium handling systems
  • Getter bed loops
  • Tritium lights manufacturing
  • Laboratory experimentation
  • Drug labeling systems

Find out more

learn more

Wall Mount Tritium-In-Air Monitor: Model 7065

We are here to ensure our customers receive industry leading products and service. 

Contact Us

Copyright © 2023 tyne usa - All Rights Reserved.


Phone:    1.877.969.TYNE  or  1.877.969.8963     Fax:   1.877.715.5508    Email: sales@tyneusa.com

  • Home
  • Tritium Monitoring System
  • Tritium Collection System
  • Tritium Handling system
  • Tritium Storage System
  • SMR Tritium Management
  • Tritium Detection Systems
  • CGD Services
  • About
  • Tritium Systems Design
  • TRITIUM MONITORS

This website uses cookies.

We use cookies to analyze website traffic and optimize your website experience. By accepting our use of cookies, your data will be aggregated with all other user data.

DeclineAccept